rated steam output 600 psi boiler

  • Offshore price : $20000-$100000 Get a quote on the right form
  • Minimum order quantity : 1 set :rated steam output 600 psi boiler
  • Supply Capacity : 10 units/month :rated steam output 600 psi boiler
  • Manufacturer/Brand : Fangkuai boiler
  • Port : Anyang
  • payment terms : Letter of Credit, Wire Transfer, VISA

Leave Your Message And Get Price!

I need the quotation of , the fuel is , this capacity is , use for . My Name is , my Email is , my WhatsApp is , Please Send the detail information for me!

Popular products

HOT

θrion Gas Fired Steam Boiler

Capacity:1-20t/h

Rated thermal efficiency: 100-104%

Fixed working pressure: ≤1.6MPa

Applicable fuel:natural gas etc.

consult
HOT

Gas(oil) Fired Integrated Hot Water Boiler

Capacity:0.7-14MW

Rated thermal efficiency:96-98%

Fixed working pressure:≤1.25MPa

Applicable fuel:Natural gas, light oil, etc.

consult
HOT

H6 Gas Fired Hot Water Boiler

Capacity:0.7-2.8Mw

Rated thermal efficiency: 97.2-106%

Fixed working pressure:0.1MPa

Applicable fuel:Natural gas, etc.

consult
HOT

T7 Vacuum Hot Water Boilerr

Capacity:2.8-7.0Mw

Rated thermal efficiency:≥105.5%

Fixed working pressure:-0.02MPa

Applicable fuel:Natural gas, etc.

consult
HOT

V6 Gas Fired Hot Water Boiler

Capacity:99Kw

Rated thermal efficiency:97.2-104.4%

Fixed working pressure:1.0MPa

Applicable fuel:Natural gas, etc.

consult
HOT

Electric Steam Boiler

Capacity:0.5-4.0 t/h

Rated thermal efficiency:98%

Fixed working pressure:≤1.25MPa

Applicable fuel:electric energy

consult

Leave us a message

We will send out plans and quotations within five minutes

Name (optional)

Email

Whatsapp

Choose product type

Message

boilermanufactory

Get display discount

boiler
Contact us

Global Sales Hotline:
0086-371-60922096

Email: [email protected]

Voicemail
  • 4-Series Waterback Boilers | Hot Water & Steam - York-Shipley

    Efficient, cost-effective and industry proven. The 4 series boiler from York-Shipley is a high efficiency wetback firetube boiler with 5 square foot of heat transfer per boiler horsepower. 150 HP York-Shipley 4 Series Boiler. 800 HP York-Shipley 4 Series Boiler. Quotes so fast, your head will spin. I'm open to suggestion!Get Price

  • Steam Calculators: Boiler Calculator

    Mar 17, 2015 · Steam, Boiler, and Blowdown Pressure are the same. Combustion Efficiency is the % of fuel energy that is directly added to the feedwater and not otherwise lost or used. Blowdown Rate is the % of incoming feedwater mass flow rate that leaves the boiler as a saturated liquid at boiler pressure.Get Price

  • Main Propulsion Plant DD445 and 692 Classes and …

    Jun 18, 2014 · For instance, if a boiler has an Input of 200,000 BTUH and a Gross Output of 160,000 BTUH, that boiler would be running at 80% combustion efficiency. It's not hard to figure this out. Just divide the big number into the little number and then multiply the result by 100 to get a percentage. And this brings us to Net Output.Get Price

  • Making Sure Steam Piping Is Safe(10 Simple Rules and

    Jun 28, 2005 · The piping attached to the steam discharge flange must also be built to withstand the MAWP that the boiler can generate. In multiple boiler installations, the design rules typically apply to all piping through the second stop valve from the discharge flange of the boiler and are governed by ASME Code Section I and B31.1.Get Price

  • 2012 Cleaver Brooks 60 HP 150 PSI Steam Boiler Oil Burner

    SOLD One used 300 HP Cleaver Brooks packaged steam boiler, model CB-100-300-150, oil fired, rated up to 10,350 pounds of steam per hour, 10.05 million btu/hr, 150 psi, controls, serial# OL101175, built 2001.Get Price

  • Used Industrial Boilers, Package Boilers, Watertube

    IEN# 126349 - 600 HP, Cleaver Brooks Model CB200-600, 150 PSI Boiler, Rated at 20,700 lbs/hr Steam. Packaged Steam Boiler is a Four (4) Pass Horizontal Design, Dual Fuel: Natural Gas and Fuel Oil Input; 25. 1 MMBtu/Hr Natural Gas 179.5 GPH Fuel Oil.Get Price

  • 400, 500 & 600 HP Boiler Models | Cleaver-Brooks | York

    The 400, 500 and 600 HP capacity range of firetube boilers covers the mid-range of industrial and large commercial facility steam plants. This size boiler is commonly requested for lumber mills using steam to power dry kilns, hospitals who need building heat & sterilization steam, and meat processing plants among other applications. 400 – 600 HP boilers come in a wide variety of …Get Price

  • STEAM TEMPERATURE PRESSURE TABLE - Milwaukee Valve

    Mar 17, 2015 · Steam, Boiler, and Blowdown Pressure are the same. Combustion Efficiency is the % of fuel energy that is directly added to the feedwater and not otherwise lost or used. Blowdown Rate is the % of incoming feedwater mass flow rate that leaves the boiler as a saturated liquid at boiler pressure.Get Price

  • CONVERSION OF BOILER IN KG/H AND KW

    CONVERSION OF BOILER IN KG/H AND KW (Approximate) G.B. and U.S.A. Steam from and at 100°C Boiler HP Kg/h 2.26MJ/kg Metric System Steam from 0°C to 100°C Kg/h 2.26MJ/kg Power In kW 1 5 10 15 20 30 40 50 60 70 80 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 15.65 78 156 235 313 470 626 783 940 1096 1252 1566 2350 3130 3915 4700 Get Price

  • IMMERSION FIRED STEAM BOILER - Distillery Trail

    250 14" 2 to 10 psi 10 psi 300-350 14" 1.5 to 10 psi 10 psi 400-800 1 psi 2 to 10 psi 10 psi steam boiler ratings, capacities, weights sea level to 3000 feet altitude boiler horse power hourly gas input (1000btu) gross hourly output (1000btu) pounds of steam per hour (1) normal water capacity (u.s. gal) flooded water weight (lbs) shipping Get Price

  • Unit Conversion--How to Calculate Boiler Horsepower

    Boiler Horsepower - BHP. The Boiler Horsepower (BHP) is the amount of energy required to produce 34.5 pounds of steam per hour at a pressure and temperature of 0 Psig and 212 ℉, with feedwater at 0 Psig and 212 ℉. "Boiler horsepower, a unit of measurement of power of steam boilers" from Wiki.Get Price

  • Miscellaneous Industrial Costs - Michigan

    BOILER RATINGS Packaged boilers are rated on the basis of maximum continuous nozzle output, in terms of boiler horsepower, B.T.U. per hour, or pounds of steam per hour at 212° F. Available information can be converted to horsepower by using the table below. 1 boiler horsepower = 33,500 B.T.U. per hour = 139 square feet of steam radiationGet Price

  • Used Steam Boilers for sale. Cleaver-Brooks equipment

    175 horse steam boiler - 300 PSI diesel or gas fired - Navy surplus rebuilt - Export available in Virginia. Manufacturer: Clayton International Four (4) Clayton 175 horsepower steam boilers rated at 300 PSIG design pressure firing #2 diesel fuel. Model #RO 175 M The four boilers are currently installed, piped and wired in a 40' long trailer. The 4 boilerGet Price

  • Used Fire Tube Package Boilers For Sale | Perry Videx

    75 HP 30 PSI Bryan CL-75W-FDG Flexible Tube Gas Fired Boiler. Stock #9884-1. Used Bryan CL-75W-FDG flexible tube gas fired boiler. 75 HP, 30 psi. Input-375-750 MBH, output-600 MBH, 90 square foot heating surface. Maximum working pressure water 30 psig, minimum relief valve capacity 900 PPH, Honeywell fluid power gas valve, 120V/1PH/60HZ .Get Price

  • Boilers For Sale | Lumbermenonline.com

    Boilers each rated for 20,700 pounds of steam per hour each. However, manufacturer specified they can be operated at 30,000 pounds per hour with dry wood or bark fuel (12 percent moisture). -- 250 PSI operating pressure ratings on each Boiler. -- VFD Drives on all main Motors. (The plant uses a maximum 75 HP for each boiler.) -- Electrical Get Price

  • Water-tube Package and Industrial Boilers » Babcock & Wilcox

    1. All package boilers are of membrane construction. 2. Because of B&W's constant effort to improve design, equipment supplied may differ slightly from that described above. * Steam capacities shown are saturated steam. Capacities will vary depending on conditions and limitations. Metric Conversions: inches x 25.4 = mm. inches x 2.54 = cmGet Price

  • Boiler Ratings Explained - Heating Help

    This tutorial explains the three most commonly used boiler ratings: The 'From and at' rating for evaporation, the kW rating for heat output, and boiler horsepower. 'From and at' rating The 'from and at' rating is widely used as a datum by shell boiler manufacturers to give a boiler a rating which shows the amount of steam in kg/h which the Get Price

  • How They Rated Radiators - Heating Help

    Aug 20, 2014 · This boiler maintained a pressure between 10- and 15-psi. They used a pressure-reducing valve to lower the pressure going to the radiators to 2 psig, or any other pressure they wanted to try. Steam left the PRV and entered a receiver designed to remove water from the steam. From there, the steam went to a steam main that led to the radiators.Get Price

  • Johnston Boiler Company Boiler Glossary - Steam & …

    Nov 03, 2006 · Steam Boilers & Appurtenances, Combustion & Instrumentation Controls, Deaerators, Exhaust Systems, Heat Exchangers, Heat Pipes, Industrial Pumps, Water Heaters, Water Softeners, Boiler Seminars, Services & Parts. 3 Common Boiler Formulas BOILER HORSE POWER What is the boiler horsepower of a boiler generating 21,500 lbs of steam per hour at …Get Price

  • Boilers For Sale | Lumbermenonline.com

    Boilers each rated for 20,700 pounds of steam per hour each. However, manufacturer specified they can be operated at 30,000 pounds per hour with dry wood or bark fuel (12 percent moisture). -- 250 PSI operating pressure ratings on each Boiler. -- VFD Drives on all main Motors. (The plant uses a maximum 75 HP for each boiler.) -- Electrical Get Price

  • 15 PSI Low Pressure Steam Boilers Power Burner Fired

    15 PSI Low Pressure Steam Boilers Models & Ratings / Power Burner Fired Rev. 12/2013 STACK / DRAFT REQUIREMENTS • UL listed for use with Type B Vent when power burner is for natural or L.P. gas fired only. • Type 304 stainless steel lined stack is required when equipped with #2 oil or combination gas & #2 oil burner.Get Price

  • Microprocessor-Based Boiler Controller Model 2250 From

    Microprocessor-Based Boiler Controller Model 2250 From Lakewood Instruments. Steam flashing detector and compensation. Rated to 486ºF @ 600 psi (252ºC @ 41.4 bar). This sensor cannot be used after a sample cooler. SR4. 4-electrode sensor, 3/4 inch NPT. Rated to 392ºF @ 250 psi (200ºC @17.2 bar).Get Price

  • Model CBLE Boilers 125-800HP

    Table A1-2. Model CB-LE Hot Water Boiler Ratings BOILER HP 125 150 200 250 300 350 400 500 600 700 750 800 RATINGS SEA LEVEL TO 700 FT Rated Steam Cap. (lbs/hr from and @ 212 °F) 4313 5175 6900 8625 10350 12075 13800 17250 20700 24150 25875 27600 Btu Output (1000 Btu/hr) 4184 5021 6695 8369 10043 11716 13390 16738 20085 23432 25106 26779Get Price

  • cost of producing 600 psi steam vs 200 psi steam in …

    Since the amount of steam delivered varies with temperature and pressure, a common expression of the boiler capacity is the heat transferred over time expressed as British Thermal Units per hour. A boilers capacity is usually expressed as kBtu/hour (1000 Btu/hour) and can be calculated as. W = (hg - hf) m (1) where. W = boiler capacity (Btu/h, kW)Get Price

  • Steam Capacity Conversion Table | Industrial Controls

    Dec 13, 2010 · Some additional conversion factors that may prove helpful are shown below. Conversion Factors. Multiply By To Get. BHP (Boiler Horsepower) 34.5 Lbs/Hr of Steam at 212°F. BHP (Boiler Horsepower) 0.069 GPM Water. BHP (Boiler Horsepower) 33,479 BTU/Hr. Lbs/Hr Steam 0.002 GPM Water. Lbs/Sq In 2.307 Feet of Water. Feet of Water (Head) 0.4335 Lbs/Sq In.Get Price

  • CLEAVER-BROOKS MODEL CB, CB-LE PACKAGED BOILER

    $25.00 U.S. Manual Part No. 750-184 8/98 CLEAVER-BROOKS MODEL CB, CB-LE PACKAGED BOILER 125 through 200 HP Fuel: Light Oil, Heavy Oil, Gas or CombinationGet Price

  • Vapor Power / HSI Electric Boilers - Smith Hughes Boilers

    Vapor Power HSI Electric Boiler. Resistance Type (208 - 600 V) Steam (up to 2500 psig and 4320 KW /14,700 lbs/hr) Hot Water (up to 415 psig and 4320 kW) Thermal Fluid Heaters & Steam Super Heaters (up to 1200° F and 2000 psig) Electrode Steam Boilers 3000-34,000KW/ 10,000-113,000PPH/ 100-500PSI. Electrode Hot Water Boilers 3000-34,000KW Get Price

  • Johnston Boiler Company Boiler Glossary - Steam & …

    Nov 03, 2006 · Steam Boilers & Appurtenances, Combustion & Instrumentation Controls, Deaerators, Exhaust Systems, Heat Exchangers, Heat Pipes, Industrial Pumps, Water Heaters, Water Softeners, Boiler Seminars, Services & Parts. 3 Common Boiler Formulas BOILER HORSE POWER What is the boiler horsepower of a boiler generating 21,500 lbs of steam per hour at …Get Price

  • POWER BOILERS ASME SECT. I & POWER PIPING - Steam …

    1. All steam line piping, valves and fittings must comply with the code for the required temperature and pressure of not less than the safety valve setting of the boiler but never less than 100 PSI. (B31.1 Para. 122.1.2). 2. Each Boiler must be fitted with a steam stop valve located at an accessible point in the steam-deliveryGet Price

  • Rules and Regulations for Boiler and Pressure Vessel

    (a) Power Boiler - A boiler in which steam or other vapor is generated at a pressure of more than l5 psi. (b) High Pressure, High-Temperature Boiler - A boiler in which water, oil, or other fluid is heated and intended for operation at pressures in excess of l60 psi and/or tem peratures in excess of 250 degrees Fahrenheit.Get Price